Internal audit simulation · Colombian SG-SST
Glare on the night shift
On the night shift, glare makes engraved metal codes hard to read. Maintenance has re-aimed the light. As an auditor from another process, check what changed at the station.

Did the first adjustment work?
Inspect the records. Choose the one that tests the criterion and flag the reading that supports your decision.
OT-14 · 16:30
Maintenance order
Maintenance re-aimed the light at P-2 and signed off the order. The record ends before the night shift begins.
D-1 · 10:20
Daytime test
The following day, all six plates were read correctly at P-2 with daylight coming through the windows. The report identifies the day shift.
N-1 · 21:40
Night test
| Plate | Reference code | Recorded reading | Flag |
|---|---|---|---|
| 1 | MX-248 | MX-248 | |
| 2 | MX-816 | MX-816 | |
| 3 | MX-537 | MX-537 | |
| 4 | MX-638 | MX-683 | |
| 5 | MX-192 | MX-192 | |
| 6 | MX-405 | MX-405 |
A second night test
Maintenance adjusted the lamp position after observing the reflection from the workstation. The following night, six new plates were tested from the same position.
N-2 · 21:45
| Plate | Reference code | Recorded reading |
|---|---|---|
| 1 | MX-754 | MX-754 |
| 2 | MX-169 | MX-169 |
| 3 | MX-846 | MX-846 |
| 4 | MX-325 | MX-325 |
| 5 | MX-671 | MX-671 |
| 6 | MX-482 | MX-482 |
Decision record
- First adjustment · action open
- Order OT-14 documents the adjustment. Five of six readings matched in N-1. Plate 4 was recorded as MX-683 against a reference of MX-638. The action stayed open.
- Follow-up · closure for the tested conditions
- After the second adjustment, N-2 documented six matches on six new plates. The sample met the criterion for station P-2 on the night shift.